YF-LV-P3E 15–24kW

Three-phase low-voltage hybrid inverter configurations in the 15–24kW range.

YF-LV-P3E 15–24kW
4Configurations
15–24 kWPower Range
48–51.2 VNominal Voltage Range

SERIES CONFIGURATIONS

Compare Configurations

Compare models in this series and choose a configuration for your inquiry.

Scroll horizontally to compare all models. Highlighted rows have different specifications.

Technical specifications by configuration
Parameter
YF-LV-P3E-15048
YF-LV-P3E-15048
YF-LV-P3E-18048
YF-LV-P3E-18048
YF-LV-P3E-20048
YF-LV-P3E-20048
YF-LV-P3E-24048
YF-LV-P3E-24048
Inverter Input/Output(Grid)
Rated Power15/15kw18/18kw20/20kw24/24kw
Rated Voltage380/400VAC, 3W+N+PE380/400VAC, 3W+N+PE380/400VAC, 3W+N+PE380/400VAC, 3W+N+PE
Rated Frequency50/60Hz50/60Hz50/60Hz50/60Hz
Power Factor Range0.8 leading ~ 0.8 lagging0.8 leading ~ 0.8 lagging0.8 leading ~ 0.8 lagging0.8 leading ~ 0.8 lagging
Switch Time<20ms<20ms<20ms<20ms
Currernt(Maximum/Continuous)43/22VAC52/26VAC58/29VAC60/35VAC
Max Output Overcurrent Protection400V AC/100A AC400V AC/100A AC400V AC/100A AC400V AC/100A AC
Battery
Battery TypeLithium or lead-acid batteryLithium or lead-acid batteryLithium or lead-acid batteryLithium or lead-acid battery
Battery Voltage Range40~60VDC40~60VDC40~60VDC40~60VDC
Rated Battery Voltage51.2V48V48V48V
Max Charge Current315A375A390A415A
Max Discharge Current315A375A390A415A
PV Input
No. of MPPT Tracker/Strings2/2+22/2+22/2+22/2+2
Max PV Array Power30kW36kW40kW48kW
Max DC Voltage1000VDC1000VDC1000VDC1000VDC
MPPT Voltage Range150~950VDC150~950VDC150~950VDC150~950VDC
Start-up Voltage180VDC180VDC180VDC180VDC
Max Input Current4*20ADC4*20ADC4*20ADC4*20ADC
Isc PV(Absolute Maximum)4*30ADC4*30ADC4*30ADC4*30ADC
AC Output(EPS)
EPS Rated Output Voltage380/400VAC, 3W+N+PE380/400VAC, 3W+N+PE380/400VAC, 3W+N+PE380/400VAC, 3W+N+PE
EPS Rated Output Frequency50/60Hz50/60Hz50/60Hz50/60Hz
EPS Rated Output Active Power15kW18kW20kW24kW
EPS Rated Output Apparent Power15kVA18kVA20kVA24kVA
EPS Rated Output Current22A AC26A AC29A AC35A AC
Overload Capacity100%600s/120%300s/150%60s/200%10s100%600s/120%300s/150%60s/200%10s100%600s/120%300s/150%60s/200%10s100%600s/120%300s/150%60s/200%10s
Efficiency
MPPT Efficiency99.90%99.90%99.90%99.90%
Euro-efficiency97.20%97.20%97.20%97.20%
Max Efficiency98.00%98.00%98.00%98.00%
Protection&Feature
Insulation MonitoringYesYesYesYes
Residual Current MonitoringYesYesYesYes
Parallel FunctionYesYesYesYes
Protection DegreeIP66IP66IP66IP66
CertificationsIEC62109-1/2,IEC62477-1,IEC61000-6-1, IEC61000-6-3,EN 50549-1&-10, NRS 097-2-1,IEC61727,IEC 61683,IEC62116IEC62109-1/2,IEC62477-1,IEC61000-6-1, IEC61000-6-3,EN 50549-1&-10, NRS 097-2-1,IEC61727,IEC 61683,IEC62116IEC62109-1/2,IEC62477-1,IEC61000-6-1, IEC61000-6-3,EN 50549-1&-10, NRS 097-2-1,IEC61727,IEC 61683,IEC62116IEC62109-1/2,IEC62477-1,IEC61000-6-1, IEC61000-6-3,EN 50549-1&-10, NRS 097-2-1,IEC61727,IEC 61683,IEC62116
Other ProtectionOutput over voltage, Output over current, Short circuit, Surge, Temperature, Anti-islandingOutput over voltage, Output over current, Short circuit, Surge, Temperature, Anti-islandingOutput over voltage, Output over current, Short circuit, Surge, Temperature, Anti-islandingOutput over voltage, Output over current, Short circuit, Surge, Temperature, Anti-islanding
General Parameter
Storage Temperature-25°C~60°C-25°C~60°C-25°C~60°C-25°C~60°C
Operating Temperature-25°C~ +60°C (Linely derating to 60% when exceed +45°C ~ +60°C)-25°C~ +60°C (Linely derating to 60% when exceed +45°C ~ +60°C)-25°C~ +60°C (Linely derating to 60% when exceed +45°C ~ +60°C)-25°C~ +60°C (Linely derating to 60% when exceed +45°C ~ +60°C)
Humidity0-95% (Non-condensing)0-95% (Non-condensing)0-95% (Non-condensing)0-95% (Non-condensing)
Altitude4000(>2000 Derating)4000(>2000 Derating)4000(>2000 Derating)4000(>2000 Derating)
Noise<75dB<75dB<75dB<75dB
Warranty5 Years5 Years5 Years5 Years
Machine Dimension(W*H*D)448*660*265mm448*660*265mm448*660*265mm448*660*265mm
Machine Weight/N.W.48kg48kg48kg48kg
Display&Communitation
DisplayLCD+APPLCD+APPLCD+APPLCD+APP
Documents & Test ConditionsDatasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.

Specifications and test conditions apply to the corresponding configuration. Refer to its datasheet for details.