PRODUCT SERIES
YF-LV-P1E 10–16kW
Single-phase hybrid inverter configurations in the 10–16kW range.

3Configurations
10–16 kWPower Range
51.2 VNominal Voltage Range
SERIES CONFIGURATIONS
Compare Configurations
Compare models in this series and choose a configuration for your inquiry.
Scroll horizontally to compare all models. Highlighted rows have different specifications.
| Parameter | ![]() | ![]() | ![]() |
|---|---|---|---|
| Inverter Input/Output(Grid) | |||
| Rated Power | 10kW | 12kW | 16kW |
| Rated Voltage | 220/230/240VAC, L+N+PE | 220/230/240VAC, L+N+PE | 220/230/240VAC, L+N+PE |
| Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
| Power Factor Range | 0.8 leading~ 0.8 lagging | 0.8 leading~ 0.8 lagging | 0.8 leading~ 0.8 lagging |
| Switch Time(ms) | <10 | <10 | <10 |
| Current(Maximum Continuous) | 43.5A | 52.2A | 69.9A |
| Max Output Overcurrent Protection | 100A | 100A | 100A |
| Battery | |||
| Battery Type | Lithium/Lead-acid | Lithium/Lead-acid | Lithium/Lead-acid |
| Battery Voltage Range | 40~60VDC | 40~60VDC | 40~60VDC |
| Rated Battery Voltage | 51.2VDC | 51.2VDC | 51.2VDC |
| Max. Charge Current | 220A | 250A | 275A |
| Max. Discharge Current | 220A | 250A | 275A |
| Reverse Connect Protection | Yes | Yes | Yes |
| PV Input | |||
| No. Of MPPT Trackers/Strings | 3/2+2+2 | 3/2+2+2 | 3/2+2+2 |
| Max. PV Array Power | 15kW | 18kW | 22.5kW |
| Max. DC Voltage Range | 550VDC | 550VDC | 550VDC |
| MPPT Voltage Range | 80~480VDC | 80~480VDC | 80~480VDC |
| Start-up Voltage | 120VDC | 120VDC | 120VDC |
| Max. Input Current | 3*26A | 3*26A | 3*26A |
| Isc PV(Absolute Max.) | 3*39A | 3*39A | 3*39A |
| AC Output(EPS) | |||
| EPS Rated Output Voltage | 220/230/240VAC, L+N+PE | 220/230/240VAC, L+N+PE | 220/230/240VAC, L+N+PE |
| EPS Rated Output Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
| EPS Rated Output Active Power | 10kW | 12kW | 16kW |
| EPS Rated Output Apparent Power | 10kVA | 12kVA | 16kVA |
| EPS Rated Output Current | 43.5A | 52.2A | 69.6A |
| Overload Capacity(Off Grid) | 110%(<60s)/120%(<30s)/150%(<10s) | 110%(<60s)/120%(<30s)/150%(<10s) | 110%(<60s)/120%(<30s)/150%(<10s) |
| Efficiency | |||
| MPPT Efficiency | 99.9% | 99.9% | 99.9% |
| Euro-efficiency | 96.5% | 96.5% | 96.5% |
| Max. Efficiency | 97.3% | 97.3% | 97.3% |
| Protection & Feature | |||
| Insulation Monitoring | Yes | Yes | Yes |
| Residual Current Monitoring | Yes | Yes | Yes |
| Parallel Function | Yes, up to 6 pcs | Yes, up to 6 pcs | Yes, up to 6 pcs |
| Protection Degree | IP66 | IP66 | IP66 |
| Certifications | ENIEC62477-1, ENIEC 62109-1/2, ENIEC61000-6-1, EN50549-1, G99, NTS631, UNE217002:2020 etc. | ENIEC62477-1, ENIEC 62109-1/2, ENIEC61000-6-1, EN50549-1, G99, NTS631, UNE217002:2020 etc. | ENIEC62477-1, ENIEC 62109-1/2, ENIEC61000-6-1, EN50549-1, G99, NTS631, UNE217002:2020 etc. |
| Other Protection | Overload, Overtemperature, Short circuit , Active anti-islanding method etc. | Overload, Overtemperature, Short circuit , Active anti-islanding method etc. | Overload, Overtemperature, Short circuit , Active anti-islanding method etc. |
| General Parameters | |||
| Storage Temperature | -25°C~60°C | -25°C~60°C | -25°C~60°C |
| Operating Temperature | -25°C~+60°C(Linely deratingto 60% when exceed +45°C~+60°C) | -25°C~+60°C(Linely deratingto 60% when exceed +45°C~+60°C) | -25°C~+60°C(Linely deratingto 60% when exceed +45°C~+60°C) |
| Humidity | 0-100%(Non-condensing) | 0-100%(Non-condensing) | 0-100%(Non-condensing) |
| Altitude | 4000(>2000 Derating) | 4000(>2000 Derating) | 4000(>2000 Derating) |
| Noise | <45dB | <45dB | <45dB |
| Machine Dimension | 600*466*252mm | 600*466*252mm | 600*466*252mm |
| Machine Weight/N.W. | 40kg | 40kg | 40kg |
| Display & Communication | |||
| Display | LCD+APP(Optional: LED+App) | LCD+APP(Optional: LED+App) | LCD+APP(Optional: LED+App) |
| Interface | CAN/RS485/Bluetooth/WiFi(Optional:4G/DRM) | CAN/RS485/Bluetooth/WiFi(Optional:4G/DRM) | CAN/RS485/Bluetooth/WiFi(Optional:4G/DRM) |
| Documents & Test Conditions | Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. | Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. | Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. |
Specifications and test conditions apply to the corresponding configuration. Refer to its datasheet for details.
Get in touch
Contact Us