PRODUCT SERIES
YF-LV-P1E 6.6–7.2kW
Single-phase hybrid inverter configurations with 6.6kW or 7.2kW rated output power.

2Configurations
6.6–7.2 kWPower Range
40 VNominal Voltage Range
SERIES CONFIGURATIONS
Compare Configurations
Compare models in this series and choose a configuration for your inquiry.
Scroll horizontally to compare all models. Highlighted rows have different specifications.
| Parameter | ![]() | ![]() |
|---|---|---|
| PV Input | ||
| Max. Input Voltage | 500V | 500V |
| Isc PV (absolute Max.) | 25A/25A | 25A/25A |
| Max. Input Current | 20A/20A | 20A/20A |
| Number of MPPT Channels | 2/1+1 | 2/1+1 |
| MPPT Range | 150~425VDC | 90~450VDC |
| Max. Input PV Power | 13200W | 13200W |
| Max. PV Input Voltage | 500V | 500V |
| Start-up Voltage | 125V | 125V |
| Battery(Charge/Discharge) | ||
| Battery Type | Lithium/Lead-acid | Lithium/Lead-acid |
| Battery Voltage Range | 40V-60V | 40V-60V |
| Max. Charge/Discharge Current | 135A | 140A |
| Charging Strategy For Li-ion Battery | Self-adaption to BMS | Self-adaption to BMS |
| Number Of Battery Input | 1 | 1 |
| AC Input/Output Data | ||
| Rated AC Input/Output Active Power | 6600W | 7200W |
| Max. AC Input/Output Apparent Power | 6600W | 7200W |
| Peak Power(Off-grid) | 2 times of rated power, 10s | 2 times of rated power, 10s |
| Rated AC Input/Output Current | 30A | 33A |
| Max. AC Input/Output Current | 30A | 33A |
| Max. Continuous AC Passthrough (grid to load) | 40A | 40A |
| Rated Input/Output Voltage Range | 220/230V 0.85Un-1.1Un | 220/230V 0.85Un-1.1Un |
| Grid Connection Form | L+N+PE | L+N+PE |
| Rated Input/Output Grid Frequency Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
| Output Power Factor(Off grid) | 1~(0.8 leading to 0.8 lagging) | 1~(0.8 leading to 0.8 lagging) |
| Output Current Harmonic Distortion | <3%(Of nominal power) | <3%(Of nominal power) |
| DC Injection Current | <0.5% ln | <0.5% ln |
| Others | ||
| Temperature | -40°C~+60°C, >45°C Derating | -40°C~+60°C, >45°C Derating |
| Inverter Isolation | DC Reverse Polarity Protection, AC Output OvercurrentProtection, Thermal Protection, AC Output Overvoltage Protection,; AC Output Short Circuit Protection, DC ComponentMonitoring, Arc Fault Circuit Interrupter (optional),Anti-islanding; Protection, DC Switch, Insulation Impedance Detection,Residual Current Detection | DC Reverse Polarity Protection, AC Output OvercurrentProtection, Thermal Protection, AC Output Overvoltage Protection,; AC Output Short Circuit Protection, DC ComponentMonitoring, Arc Fault Circuit Interrupter (optional),Anti-islanding; Protection, DC Switch, Insulation Impedance Detection,Residual Current Detection |
| Overvoltage Category | OVC Ⅲ(AC Main), OVC Ⅱ(PV) | OVC Ⅲ(AC Main), OVC Ⅱ(PV) |
| Dimensions, D*W*H(mm) | 338*480*205mm | 338*480*205mm |
| Weight | 13kg | 13kg |
| Documents & Test Conditions | Datasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. | Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. |
Specifications and test conditions apply to the corresponding configuration. Refer to its datasheet for details.