PRODUCT SERIES

YF-LV-P1E 6.6–7.2kW

Single-phase hybrid inverter configurations with 6.6kW or 7.2kW rated output power.

YF-LV-P1E 6.6–7.2kW
2Configurations
6.6–7.2 kWPower Range
40 VNominal Voltage Range

SERIES CONFIGURATIONS

Compare Configurations

Compare models in this series and choose a configuration for your inquiry.

Scroll horizontally to compare all models. Highlighted rows have different specifications.

Technical specifications by configuration
Parameter
YF-LV-P1E-6648
YF-LV-P1E-6648
YF-LV-P1E-7248
YF-LV-P1E-7248
PV Input
Max. Input Voltage500V500V
Isc PV (absolute Max.)25A/25A25A/25A
Max. Input Current20A/20A20A/20A
Number of MPPT Channels2/1+12/1+1
MPPT Range150~425VDC90~450VDC
Max. Input PV Power13200W13200W
Max. PV Input Voltage500V500V
Start-up Voltage125V125V
Battery(Charge/Discharge)
Battery TypeLithium/Lead-acidLithium/Lead-acid
Battery Voltage Range40V-60V40V-60V
Max. Charge/Discharge Current135A140A
Charging Strategy For Li-ion BatterySelf-adaption to BMSSelf-adaption to BMS
Number Of Battery Input11
AC Input/Output Data
Rated AC Input/Output Active Power6600W7200W
Max. AC Input/Output Apparent Power6600W7200W
Peak Power(Off-grid)2 times of rated power, 10s2 times of rated power, 10s
Rated AC Input/Output Current30A33A
Max. AC Input/Output Current30A33A
Max. Continuous AC Passthrough (grid to load)40A40A
Rated Input/Output Voltage Range220/230V 0.85Un-1.1Un220/230V 0.85Un-1.1Un
Grid Connection FormL+N+PEL+N+PE
Rated Input/Output Grid Frequency Range50Hz/45Hz-55Hz 60Hz/55Hz-65Hz50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Output Power Factor(Off grid)1~(0.8 leading to 0.8 lagging)1~(0.8 leading to 0.8 lagging)
Output Current Harmonic Distortion<3%(Of nominal power)<3%(Of nominal power)
DC Injection Current<0.5% ln<0.5% ln
Others
Temperature-40°C~+60°C, >45°C Derating-40°C~+60°C, >45°C Derating
Inverter IsolationDC Reverse Polarity Protection, AC Output OvercurrentProtection, Thermal Protection, AC Output Overvoltage Protection,; AC Output Short Circuit Protection, DC ComponentMonitoring, Arc Fault Circuit Interrupter (optional),Anti-islanding; Protection, DC Switch, Insulation Impedance Detection,Residual Current DetectionDC Reverse Polarity Protection, AC Output OvercurrentProtection, Thermal Protection, AC Output Overvoltage Protection,; AC Output Short Circuit Protection, DC ComponentMonitoring, Arc Fault Circuit Interrupter (optional),Anti-islanding; Protection, DC Switch, Insulation Impedance Detection,Residual Current Detection
Overvoltage CategoryOVC Ⅲ(AC Main), OVC Ⅱ(PV)OVC Ⅲ(AC Main), OVC Ⅱ(PV)
Dimensions, D*W*H(mm)338*480*205mm338*480*205mm
Weight13kg13kg
Documents & Test ConditionsDatasheet ↗Manual ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.

Specifications and test conditions apply to the corresponding configuration. Refer to its datasheet for details.