Get a Quote ↗

PRODUCT SERIES

YF-FS-HP-SP

High-frequency solar inverter configurations in the SP series.

YF-FS-HP-SP
3Configurations

SERIES CONFIGURATIONS

Compare Configurations

Compare models in this series and choose a configuration for your inquiry.

Scroll horizontally to compare all models. Highlighted rows have different specifications.

Technical specifications by configuration
Parameter
YF-FS-HP4024SP
YF-FS-HP4024SP
YF-FS-HP6248SP
YF-FS-HP6248SP
YF-FS-HP11048SP
YF-FS-HP11048SP
Input
Input FormationL+N+PEL+N+PEL+N+PE
Rated Input Voltage220/230/240VAC220/230/240VAC220/230/240VAC
Input Voltage Range90-280VAC±3V(Normal Mode)/170-280VAC±3V(UPS Mode)90-280VAC±3V(Normal Mode)/170-280VAC±3V(UPS Mode)90-280VAC±3V(Normal Mode)/170-280VAC±3V(UPS Mode)
Frequency Range50/60Hz±5%50/60Hz±5%50/60Hz±5%
Output
Rated Power(Battery Inverter)4000W6200W11000W
Rated Power(PV Inverter)4500W6500W15000W
Output Voltage220/230/240VAC220/230/240VAC220/230/240VAC
Output Frequency50/60Hz±0.1%50/60Hz±0.1%50/60Hz±0.1%
Output WavePure Sine WavePure Sine WavePure Sine Wave
Transfer TimeComputer equipment 10ms, household appliances 20msComputer equipment 10ms, household appliances 20msComputer equipment 10ms, household appliances 20ms
Peak Power8000VA12400VA22000VA
Overload AbilityBattery Mode: 11s@105%-150% Load 2s@150%-200% Load 400ms@105%-150% LoadBattery Mode: 11s@105%-150% Load 2s@150%-200% Load 400ms@105%-150% LoadBattery Mode: 11s@105%-150% Load 2s@150%-200% Load 400ms@105%-150% Load
Grid-connected Operation
Output Voltage220/230/240VAC220/230/240VAC220/230/240VAC
Grid Voltage Range170-265VAC170-265VAC170-265VAC
Grid Frequency Range49-51±1Hz/59-61±1Hz49-51±1Hz/59-61±1Hz49-51±1Hz/59-61±1Hz
Output Current17.4A26.9A47.8A
Power Factor Range>0.99>0.99>0.99
Conversion Efficiency(DC/AC)98%98%98%
Battery
Rated Voltage24VDC48VDC48VDC
Constant Charging Voltage(Adjustable)28.2VDC56.4VDC56.4VDC
Float Charging Voltage(Adjustable)27VDC54VDC54VDC
Charger
PV Charging MethodMPPTMPPTDual MPPT
Max. PV Input Power6500W8500W2*7500W
MPPT Tracking Range60-500VDC60-500VDC90-500VDC
Optimal VMP Working Range300-400VDC300-400VDC360-430VDC
Max. PV Input Voltage500VDC500VDC500VDC
Max. PV Input Current27A27A27A/27A
Max. PV Charging Current120A120A150A
Max. AC Charging Current100A100A150A
Max. Charging Current120A120A150A
Display
LCD InterfaceCan display operating mode/load/input/outputCan display operating mode/load/input/outputCan display operating mode/load/input/output
Interface
RS232Baud Rate 2400Baud Rate 2400Baud Rate 2400
Expansion Slot Communication InterfaceLithium Battery BMS Communication Card, WiFl /Pitch2.54mmLithium Battery BMS Communication Card, WiFl /Pitch2.54mmLithium Battery BMS Communication Card, WiFl /Pitch2.54mm
Parallel interfaceNot Support ParallelSupport ParallelSupport Parallel
Ambient Parameters
Operating Temperature-10°C~50°C-10°C~50°C-10°C~50°C
Operating Environment Humidity-15°C~60°C-15°C~60°C-15°C~60°C
Storage Temperature20%~90%(No condensation)20%~90%(No condensation)20%~90%(No condensation)
Noise≤50dB≤50dB≤50dB
Documents & Test ConditionsDatasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice.

Specifications and test conditions apply to the corresponding configuration. Refer to its datasheet for details.

Get in touch

Contact Us

Contact us for product information or a quote.