PRODUCT SERIES
YF-LV-P3E 8–12kW
Three-phase low-voltage hybrid inverter configurations for 48V battery systems.

3Configurations
8–12 kWPower Range
48 VNominal Voltage Range
SERIES CONFIGURATIONS
Compare Configurations
Compare models in this series and choose a configuration for your inquiry.
Scroll horizontally to compare all models. Highlighted rows have different specifications.
| Parameter | ![]() | ![]() | ![]() |
|---|---|---|---|
| Battery Input Data | |||
| Battery Type | Lithium or lead-acid battery | Lithium or lead-acid battery | Lithium or lead-acid battery |
| Rated Battery Voltage | 48V | 48V | 48V |
| Maximum Charging Voltage | ≤60V(Configurable) | ≤60V(Configurable) | ≤60V(Configurable) |
| Maximum Charge/discharge Current | 190A | 210A | 250A |
| PV Input Data | |||
| Maximum DC Input Power | 16000W | 20000W | 24000W |
| Maximum DC Input Voltage | 1000V | 1000V | 1000V |
| MPPT Operating Voltage Range | 200V~800V | 200V~800V | 200V~800V |
| Starting Voltage | 150V | 150V | 150V |
| Maximum Input Current | 18/18A | 36/18A | 36/18A |
| MPPT Number | 2 | 2 | 2 |
| AC Output Parameters(ON-GRID) | |||
| Maximum Output Apparent Power | 8800W | 11000W | 13200W |
| Rated Output Voltage | 380/400V | 380/400V | 380/400V |
| Rated Output Frequency | 50 Hz/60 Hz | 50 Hz/60 Hz | 50 Hz/60 Hz |
| Max. Output Current | 13.3A | 16.7A | 20A |
| Output Power Factor | 1(-0.8 leading~+0.8lagging) | 1(-0.8 leading~+0.8lagging) | 1(-0.8 leading~+0.8lagging) |
| AC Output Parameters(OFF-GRID) | |||
| Rated Output Apparent Power | 8000W | 10000W | 12000W |
| Maximum Output Apparent Power | >200%, 15sec | >200%, 15sec | >200%, 15sec |
| Rated Output Voltage | 380/400V | 380/400V | 380/400V |
| Rated Output Frequency | 50 Hz/60 Hz | 50 Hz/60 Hz | 50 Hz/60 Hz |
| Max. Output Current | 13.3A | 16.7A | 20A |
| Efficiency | |||
| MPPT. Efficiency | 98% | 98% | 98% |
| Max. Efficiency | 94.5% | 94.5% | 94.5% |
| Europe Efficiency | 97.5% | 97.5% | 97.5% |
| Protection | |||
| PV Input Reverse Polarity Protection | Yes | Yes | Yes |
| PV Insulation Resistance Detection | Yes | Yes | Yes |
| Residual Current Detection | Yes | Yes | Yes |
| Output Over Current Protection | Yes | Yes | Yes |
| Output Short Circuit Protection | Yes | Yes | Yes |
| Output Over Voltage Protection | Yes | Yes | Yes |
| Basic Data | |||
| Parallel Interface | MAX. 8 units in parallel | MAX. 8 units in parallel | MAX. 8 units in parallel |
| Operation Temperature | -25°C~60°C(Frequency-decreasing above 45°C) | -25°C~60°C(Frequency-decreasing above 45°C) | -25°C~60°C(Frequency-decreasing above 45°C) |
| Storage Temperature | -30°C~65°C | -30°C~65°C | -30°C~65°C |
| Relative Humidity | 0~95% | 0~95% | 0~95% |
| Working Altitude | ≤4000m(Frequency-decreasing above 2000m) | ≤4000m(Frequency-decreasing above 2000m) | ≤4000m(Frequency-decreasing above 2000m) |
| Cooling | Intelligent Forced Air Cooling | Intelligent Forced Air Cooling | Intelligent Forced Air Cooling |
| Noise | <55dB | <55dB | <55dB |
| Weight | 38kg | 38kg | 38kg |
| Dimensions (W*H*D) | 475*683*256mm | 475*683*256mm | 475*683*256mm |
| Protection Class | IP66 | IP66 | IP66 |
| Topology | HF Isolation(Battery Side) | HF Isolation(Battery Side) | HF Isolation(Battery Side) |
| Standard | |||
| Safety Standard/EMC Standard | NBIT32004-2018, IEC62109, IEC61000, IS16169 &IS16221(BIS) | NBIT32004-2018, IEC62109, IEC61000, IS16169 &IS16221(BIS) | NBIT32004-2018, IEC62109, IEC61000, IS16169 &IS16221(BIS) |
| Grid-connected Standard | IEC61727, EN50549-1, VDE-4105, NRS-097-2-1, OVE-Richtlinie R25, UNE217001/2, Ordinace No.140 | IEC61727, EN50549-1, VDE-4105, NRS-097-2-1, OVE-Richtlinie R25, UNE217001/2, Ordinace No.140 | IEC61727, EN50549-1, VDE-4105, NRS-097-2-1, OVE-Richtlinie R25, UNE217001/2, Ordinace No.140 |
| Other Standard | IEC61683, IEC62116, EN50530, IEC60068 | IEC61683, IEC62116, EN50530, IEC60068 | IEC61683, IEC62116, EN50530, IEC60068 |
| Documents & Test Conditions | Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. | Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. | Datasheet ↗*Test conditions: 0.5C charge/discharge, @25°C, 80% DOD; product specifications are subject to change without prior notice. |
Specifications and test conditions apply to the corresponding configuration. Refer to its datasheet for details.
Get in touch
Contact Us
Contact us for product information or a quote.